RSS-Quant

โ˜ย  +38 098 527 9888 ย  ย โœ‰ย  quant.ua.online@gmail.com

  • UAUA
  • RURU
  • ENEN
QUANT.UA
QUANT.UA
QUANT.UA
Menu
QUANT.UA
0 items / 0 ₴
Login / Register
Sign inCreate an Account

Lost your password?
  • Blog
  • Our products
    • Quant โ€“ technical features (EN)
    • Download Instructions
    • Video Reviews
    • FAQ
  • Blacklist
  • Become a partner
    • Become a partner
    • Partners
  • Contacts
  • About
    • About Quant company
    • Documentation
  • Warranty
Login / Register
Sign inCreate an Account

Lost your password?
0 items / 0 ₴

โ˜ย  +38 098 527 9888

HomeVoltage regulator Three-phase inverter voltage regulator Quant-54 (3ั…18)
Previous product
Three-phase inverter voltage regulator Quant-42 (3ั…14) 117 540 ₴
Back to products
Next product
ะ†ะฝะฒะตั€ั‚ะพั€ะฝะธะน ัั‚ะฐะฑั–ะปั–ะทะฐั‚ะพั€ ะฝะฐะฟั€ัƒะณะธ Quant - ะ˜ะฝะฒะตั€ั‚ะพั€ะฝั‹ะน ัั‚ะฐะฑะธะปะธะทะฐั‚ะพั€ ะฝะฐะฟั€ัะถะตะฝะธั Quant
Three-phase Load Synchronizer (Phase Control Unit) โ€“ Quant 4 980 ₴ – 14 100 ₴
Sold out
Click to enlarge
Quant

Three-phase inverter voltage regulator Quant-54 (3ั…18)

157 500 ₴

The Quant inverter voltage regulator is a modern regulator that regulates the voltage spikes before they reach the output of the regulator.

The principle of operation: when a voltage surge occurs at the input of the regulator, it will take up to 10 microseconds for this surge to reach your household appliances through the regulator filters. Thus, there is a time delay between the input and output voltage. In these tens of microseconds, the Quant regulator has time to react and make the output voltage nominal 220 V and 100% safe for consumption.

Our merit – safe voltage!

Out of stock

SKU: QUANT-54-3F Category: Voltage regulator
Share
  • Description
  • Additional information
  • Reviews (0)
  • Quant ั€ะตะบะพะผะตะฝะดัƒั”!
Description

Quant-54 is a three-phase regulator with the possibility of single-phase operation and the phase control unit. Quant-54 is a three Quant-18 single-phase inverter voltage regulators, operating in pair with a phase control unit. The main difference between Quant-54 and a conventional three-phase regulator with a synchronizer is that it does not block the operation of single-phase consumers, even if for some reason there are no two phases.

Quant-54 is a voltage regulator with an advanced protection without energy accumulation. The regulator catches all surges and voltage spikes. Everything that happens at the input does not affect the output in any way. The output will always be the nominal voltage value – 220 V or 230 V at the consumer’s choice, because during the process of double conversion all harmful pulses and voltage spikes are eliminated, so the load is under reliable protection of the regulator.

Some types of three-phase loads require that all three phases:

  • are active simultaneously (the absence of one of the phases can cause an accident);
  • do not have large phase deviations in magnitude (voltage with permissible variation);
  • have the correct alternation of phases (when connected, you can always swap two phases so that the alternation is correct and the motors of the equipment rotate in the right direction, but it happens that when repairing equipment after an accident, such as a machine, electricians can swap phases so that the consumer does not aware of it, and this will lead to equipment failure;
  • are shifted to the correct angle of 120 ยฐ (the incorrect position may be, for example, if at the input of adjacent phases accidentally connected the same phase).

Our phase control unit is based on a multifunctional device for protection of phase control relays RNPP 311M manufactured by Novatek-Electro and Schneider Electric magnetic starters.

You can buy all the components separately and mount everything yourself in the general electric service panel on the site, or you can buy our ready-made mini-electric cabinet, in which everything is already assembled, and wires for connection to the outputs of the regulators (on their all three zero terminals) are brought out. Also, at the request of the customer and at their personal discretion, it is possible to reduce the cost of the phase control unit approximately to 30%, having replaced Schneider Electric automatic equipment with an E.Next automatic equipment.

When using our phase control unit in a separate casing, you get many advantages over the so-called “three-phase” regulator in one casing with a built-in phase control relay. The reliability of supplying the correct three-phase power to the corresponding three-phase loads is increased. The fact is that the absence or change of phase alternation can be caused by damage (and/or poor repair) to the cable after the regulator. If it was a so-called “three-phase” regulator in one casing, then to increase safety you need to put a phase control relay with a starter right next to the three-phase loads, for additional protection against disappearing (broken cable) or changing the direction of the motor (repaired broken cable and connected in the wrong order). But if you have already placed our unit near the load, then you do not need to do anything for quality work of three-phase loads, they are already protected, and regulators will eliminate phase imbalance voltage, and the location of synchronization, phase control will be optimally safe.

Any logistics (service, installation, delivery) are simplified by the low weight of a single-phase regulator. QUANT places great emphasis on logistical convenience, because a healthy human spine is more important than any technology. While any QUANT product by weight does not exceed 16 kg, including, for example – 3*16 kg when installed in a 3*18 kW three-phase regulator, 16 kg can easily be carried by one person, and 48 kg is a serious load for the spine.

Parameters Quant-54
Regulation type Inverter with advanced protection
Number of steps There are no steps. Smooth adjustment.
Output power per phase at an input voltage of 220V, kW 17,6
Output power for all three phases at an input voltage of 220V, kW 52,8
Output power per phase at an input voltage of 110V, kW 8,8
Output power per phase at an input voltage of 110V, kW 26,4
Output power, V 220 or 230
Output voltage correction, % “+/- 3% at a pitch of 0,1%”
Long-term input or output current per phase is not more, ะ 80
Overload current and short circuit, ะ 140
Off time with load <150%, sec. 12
Off time with load >150% – short circuit, sec. 1,5
Regulation accuracy, % 0,5
Input voltage range, V 90-350
Regulation range, V 90-350
Operating frequency range, Hz 45-50
Operating temperature range, ยฐะก .+5 โ€ฆ+40
Humidity range, % 40โ€ฆ80
Delay before switching on, sec. 6
Mounting method Hinged
Protection index ะ†ะ 20
Cooling Forced. Low-noise.
Number of phases 3
Generator compatibility No
Presence of a phase control relay Yes
Synchronization of the output voltage phase with the input voltage phase Yes
Reactive load current compensator function Yes
Current limiting function Yes
Power measurement Yes
Mechanical Bypass Yes
Soft start function Yes
Display Yes
Output receptacle 220/230 V Yes
Color Light grey
Power consumption, W 25
Dimensions of one unit, mm., HxWxD 470ั…330ั…130
Weight of one unit, kg 16
Warranty,months 60
Additional warranty, months 60
Country of origin Ukraine, Zhytomyr
Country of brand registration Ukraine
Goods manufacturer LLC RPF QUANT-INGINEERING
Additional information
ะ‘ั€ะตะฝะด

Quant

ะšั–ะปัŒะบั–ัั‚ัŒ ั„ะฐะท

3

ะŸะพั‚ัƒะถะฝั–ัั‚ัŒ, ะบะ’ั‚

54

ะะพะผั–ะฝะฐะปัŒะฝะธะน ะฒั…ั–ะดะฝะธะน ัั‚ั€ัƒะผ, ะ

80

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Three-phase inverter voltage regulator Quant-54 (3ั…18)” Cancel reply

Your email address will not be published. Required fields are marked *

Quant ั€ะตะบะพะผะตะฝะดัƒั”!
ะกั‚ะฐะฑะธะปะธะทะฐั‚ะพั€ั‹ ะฝะฐะฟั€ัะถะตะฝะธั Quant / ะกั‚ะฐะฑั–ะปั–ะทะฐั‚ะพั€ะธ ะฝะฐะฟั€ัƒะณะธ Quant

ะกั‚ะฐะฑั–ะปั–ะทะฐั‚ะพั€ะธ ะฝะฐะฟั€ัƒะณะธ Quant: ะฟะพะฒะตั€ะฝะตะฝะฝั ะตะฝะตั€ะณั–ั— ะฒ ะผะตั€ะตะถัƒ

ะกั‚ะฐะฑะธะปะธะทะฐั‚ะพั€ั‹ ะฝะฐะฟั€ัะถะตะฝะธั Quant / ะกั‚ะฐะฑั–ะปั–ะทะฐั‚ะพั€ะธ ะฝะฐะฟั€ัƒะณะธ Quant

ะกั‚ะฐะฑั–ะปั–ะทะฐั‚ะพั€ะธ ะฝะฐะฟั€ัƒะณะธ Quant: ะฟะฐั€ะฐะปะตะปัŒะฝะฐ ั€ะพะฑะพั‚ะฐ / ะฟะพั‚ัƒะถะฝั–ัั‚ัŒ / ะฑะตะทะฒั–ะดะผะพะฒะฝั–ัั‚ัŒ / ะณะฐั€ัั‡ะฐ ะทะฐะผั–ะฝะฐ

ะกั‚ะฐะฑั–ะปั–ะทะฐั‚ะพั€ะธ ะฝะฐะฟั€ัƒะณะธ Quant: cะฟั€ะฐะฒะถะฝั ัะบั€ะธั‚ะฝั–ัั‚ัŒ – ั†ะต ะผะฐะปั– ั€ะพะทะผั–ั€ะธ ั– ะฒะฐะณะฐ

ะกั‚ะฐะฑะธะปะธะทะฐั‚ะพั€ั‹ ะฝะฐะฟั€ัะถะตะฝะธั Quant / ะกั‚ะฐะฑั–ะปั–ะทะฐั‚ะพั€ะธ ะฝะฐะฟั€ัƒะณะธ Quant

ะกั‚ะฐะฑั–ะปั–ะทะฐั‚ะพั€ะธ ะฝะฐะฟั€ัƒะณะธ Quant: ะบะพะผะฟะตะฝัะฐั‚ะพั€ ั€ะตะฐะบั‚ะธะฒะฝะพัั‚ั– (ัะพั†ั–ะฐะปัŒะฝะฐ ั„ัƒะฝะบั†ั–ั ั– ะตะบะพะฝะพะผั–ั)

ะกั‚ะฐะฑั–ะปั–ะทะฐั‚ะพั€ะธ ะฝะฐะฟั€ัƒะณะธ Quant: ะฝะตะฟะพะผั–ั‚ะฝั–ัั‚ัŒ

ะกั‚ะฐะฑะธะปะธะทะฐั‚ะพั€ั‹ ะฝะฐะฟั€ัะถะตะฝะธั Quant / ะกั‚ะฐะฑั–ะปั–ะทะฐั‚ะพั€ะธ ะฝะฐะฟั€ัƒะณะธ Quant

ะกั‚ะฐะฑั–ะปั–ะทะฐั‚ะพั€ะธ ะฝะฐะฟั€ัƒะณะธ Quant: ะทะฐั…ะธัั‚ ะฒั–ะด ะฟะตั€ะตะฝะฐะฟั€ัƒะณ ัะบ ั‰ะธั‚

ะกั‚ะฐะฑะธะปะธะทะฐั‚ะพั€ั‹ ะฝะฐะฟั€ัะถะตะฝะธั Quant / ะกั‚ะฐะฑั–ะปั–ะทะฐั‚ะพั€ะธ ะฝะฐะฟั€ัƒะณะธ Quant

ะกั‚ะฐะฑั–ะปั–ะทะฐั‚ะพั€ะธ ะฝะฐะฟั€ัƒะณะธ Quant: ะผะพะดัƒะปัŒะฝะฐ ะบะพะฝัั‚ั€ัƒะบั†ั–ั ะฟะพะบั€ะฐั‰ัƒั” ัะตั€ะฒั–ั

ะกั‚ะฐะฑะธะปะธะทะฐั‚ะพั€ั‹ ะฝะฐะฟั€ัะถะตะฝะธั Quant / ะกั‚ะฐะฑั–ะปั–ะทะฐั‚ะพั€ะธ ะฝะฐะฟั€ัƒะณะธ Quant

ะกั‚ะฐะฑั–ะปั–ะทะฐั‚ะพั€ะธ ะฝะฐะฟั€ัƒะณะธ Quant: ะทะฐั…ะธัั‚ ะฟะพ ัั‚ั€ัƒะผัƒ (ะทะฐั…ะธั‰ะฐั”ะผะพ ัะตะฑะต ั– ััƒัั–ะดั–ะฒ)

ะกั‚ะฐะฑะธะปะธะทะฐั‚ะพั€ั‹ ะฝะฐะฟั€ัะถะตะฝะธั Quant / ะกั‚ะฐะฑั–ะปั–ะทะฐั‚ะพั€ะธ ะฝะฐะฟั€ัƒะณะธ Quant

ะกั‚ะฐะฑั–ะปั–ะทะฐั‚ะพั€ะธ ะฝะฐะฟั€ัƒะณะธ Quant: ะฒะธะฟั€ะฐะฒะปะตะฝะฝั ั„ะพั€ะผะธ ัะธะฝัƒัะฐ

ะกั‚ะฐะฑะธะปะธะทะฐั‚ะพั€ั‹ ะฝะฐะฟั€ัะถะตะฝะธั Quant / ะกั‚ะฐะฑั–ะปั–ะทะฐั‚ะพั€ะธ ะฝะฐะฟั€ัƒะณะธ Quant

ะกั‚ะฐะฑั–ะปั–ะทะฐั‚ะพั€ะธ ะฝะฐะฟั€ัƒะณะธ Quant: cั‚ะฐะฑั–ะปั–ะทะฐั‚ะพั€ ัะบ ั„ั–ะปัŒั‚ั€ ั– ะทะฐั…ะธัั‚

ะกั‚ะฐะฑะธะปะธะทะฐั‚ะพั€ั‹ ะฝะฐะฟั€ัะถะตะฝะธั Quant / ะกั‚ะฐะฑั–ะปั–ะทะฐั‚ะพั€ะธ ะฝะฐะฟั€ัƒะณะธ Quant

ะกั‚ะฐะฑั–ะปั–ะทะฐั‚ะพั€ Quant ั– ั€ะตะทะตั€ะฒะฝะต ะถะธะฒะปะตะฝะฝั. ะ‘ะปะพะบ ั–ะฝั‚ะตะณั€ะฐั†ั–ั— ะท ะณะตะฝะตั€ะฐั‚ะพั€ะพะผ

ะกั‚ะฐะฑั–ะปั–ะทะฐั‚ะพั€ะธ ะฝะฐะฟั€ัƒะณะธ Quant: ั–ะฝะฒะตั€ั‚ะพั€ะฝั– ัั‚ะฐะฑั–ะปั–ะทะฐั‚ะพั€ะธ ะฝะฐะฟั€ัƒะณะธ ะดั€ัƒะณะพะณะพ ะฟะพะบะพะปั–ะฝะฝั

Related products

Add to basket
Quick view
Close

Three-phase inverter voltage regulator Quant-21 (3ั…7)

82 224 ₴
Add to basket
Quick view
Close

Three-phase inverter voltage regulator Quant-33 (3ั…11)

109 050 ₴
Add to basket
Quick view
Close

Three-phase inverter voltage regulator Quant-108 (6ั…18)

344 040 ₴
Add to basket
Quick view
Close

Three-phase inverter voltage regulator Quant-42 (3ั…14)

117 540 ₴
Add to basket
Quick view
Close

Inverter voltage regulator Quant-7

25 500 ₴
Sold out
Read more
Quick view
Close

Three-phase inverter voltage regulator Quant-27 (3ั…9)

94 860 ₴
Add to basket
Quick view
Close

Three-phase inverter voltage regulator Quant-66 (6ั…11)

233 484 ₴
Add to basket
Quick view
Close

Inverter voltage regulator Quant-14

36 280 ₴
ยฉ 2022 Quant - ะ†ะฝะฒะตั€ั‚ะพั€ะฝั– ัั‚ะฐะฑั–ะปั–ะทะฐั‚ะพั€ะธ ะฝะฐะฟั€ัƒะณะธ. ะ’ัั– ะฟั€ะฐะฒะฐ ะทะฐั…ะธั‰ะตะฝั–.
  • Blog
  • Our products
    • Quant โ€“ technical features (EN)
    • Download Instructions
    • Video Reviews
    • FAQ
  • Blacklist
  • Become a partner
    • Become a partner
    • Partners
  • Contacts
  • About
    • About Quant company
    • Documentation
  • Warranty
  • Login / Register
Shopping cart
close
Start typing to see posts you are looking for.